Can't see the region you're looking for? You can find a list of our global locations here
Fire behaviour tested in acc. with Classified in acc. with |
EN ISO 9239-1 EN ISO 11925-2 EN 13501-1 |
≥ 8 kW/m² Pass Bfl-s1 |
|
Slip resistance | EN 13893 EN 16165 Annex B / ASR A1.5 EN 13845 Annex C EN 16165 Annex A |
≥ 0.30 / DS R10 ESb C |
|
Sound insulation | EN ISO 140-8 | ca. 13 dB | |
Flooring type | EN 13845 | Safety flooring | |
Thickness | EN ISO 24346 | 2 mm | |
Wear layer thickness | EN ISO 24340 | 2 mm | |
Roll dimensions | EN ISO 24341 | 2 m x 20 m = 40 m² | |
Weight | EN ISO 23997 | 2.8 kg/m² | |
Residual indentation | EN ISO 24343-1 | ≤ 0.10 mm | |
Classification for use | EN ISO 10874 | 34, 43 | |
Flexibility | EN ISO 24344 | Pass | |
Dimensional Stability | EN ISO 23999 | ≤ 0.4 % | |
Light fastness | EN ISO 105-BO2 | ≥ 6 | |
Castor chair abrasion | ISO 4918 | Yes, type W | |
Wear resistance | EN 13845 Annex D | ≤ 10% / 50000 cycles | |
Chemical resistance | EN ISO 26987 | Good | |
Under floor heating | EN 12524 | Suitable | |
Electrical behaviours | EN 1815 | ≤ 2 kV Antistatic | |
VOC emissions | CDPH 1350 / Floorscore | Approved |
*Information sur le niveau d‘émission de substances volatiles dans l‘air intérieur, présentant un risque de toxicité par inhalation, sur une échelle de classe allant de A+ (très faibles émissions) à C (fortes émissions)
Please refer to Altro installation and maintenance instructions. Failure to follow these instructions can affect product performance. Some materials are known to cause staining on vinyl floors. Typical examples include: asphalt and bitumen materials, cardboard / hardboard (wet), dyes from printed literature or packaging, rubber-backed carpets and rubber mats and rubber furniture rests and trolley wheels. Technical information on installation and staining can be found at www.altro.com/uk